- alias: Ventilation bypass and power control
description: In summer, the bypass is activated and power increased for free cooling
or deactived to preserve the cool air in house.
mode: single
triggers:
- entity_id:
- sensor.bypass_status
from: null
trigger: state
- entity_id:
- sensor.ntc1_temperature
for:
hours: 0
minutes: 5
seconds: 0
above: 28
trigger: numeric_state
- entity_id:
- sensor.ntc1_temperature
for:
hours: 0
minutes: 5
seconds: 0
below: 28
trigger: numeric_state
- entity_id:
- sensor.ntc1_temperature
for:
hours: 0
minutes: 5
seconds: 0
above: 21
trigger: numeric_state
- entity_id:
- sensor.ntc1_temperature
for:
hours: 0
minutes: 5
seconds: 0
below: 21
trigger: numeric_state
conditions: []
actions:
- if:
- condition: numeric_state
entity_id: sensor.bypass_status
above: 2
below: 4
- condition: numeric_state
entity_id: sensor.bypass_mode
below: 1
- condition: numeric_state
entity_id: sensor.ntc1_temperature
below: 21
- condition: numeric_state
entity_id: sensor.ntc2_temperature
above: 20
then:
- metadata: {}
data:
hub: brink_flair
slave: 20
value: 1
address: 8000
action: modbus.write_register
- metadata: {}
data:
hub: brink_flair
slave: 20
address: 8001
value: 2
action: modbus.write_register
else:
- if:
- condition: numeric_state
entity_id: sensor.ntc1_temperature
above: 28
then:
- metadata: {}
data:
hub: brink_flair
slave: 20
value: 1
address: 8000
action: modbus.write_register
- metadata: {}
data:
hub: brink_flair
slave: 20
address: 8001
value: 0
action: modbus.write_register
else:
- metadata: {}
data:
hub: brink_flair
slave: 20
address: 8000
value: 0
action: modbus.write_register
- alias: Ventilation time and date steering
description: Synchronize the time and date of the Brink Flair ventilation system
with the Home Assistant system time.
mode: single
triggers:
- at: 03:00:00
trigger: time
conditions: []
actions:
- metadata: {}
data:
hub: brink_flair
address: 6904
slave: 20
value: '{{now().year | int(base=16) }}'
action: modbus.write_register
- metadata: {}
data:
hub: brink_flair
address: 6903
slave: 20
value: '{% set month = now().month | int(base=16) %} {% set day = now().day
| int(base=16) %} {% set msb = month %} {% set lsb = day * (2 ** 8) %}
{{ msb + lsb }}
'
action: modbus.write_register
- metadata: {}
data:
hub: brink_flair
address: 6905
slave: 20
value: '{% set hours = now().hour | int(base=16) %} {% set minutes = now().minute
| int(base=16) %} {% set msb = hours %} {% set lsb = minutes * (2 ** 8) %}
{{ msb + lsb }}
'
action: modbus.write_register